Description
Transporter de l’énergie exprimée pour 1 A sur une distance de 1 km pendant 30 années et un taux d’utilisation de 70 %, en conformité avec les caractéristiques techniques des produits.La durée et le taux d’utilisation correspondent à l’application ‘Résidentiel / Tertiaire / industriel’ telle que définie dans le tableau donné en Annexe 1 des règles spécifiques aux Fils, Câbles et Matériels de raccordement.
Indicator |
Unit |
Total |
Manufacturing |
Distribution |
Installation |
Use |
End of Life |
Use B1 |
Maintenance B2 |
Repair B3 |
Replacement B4 |
Refurbishment B5 |
Operational energy use B6 |
Operational water use B7 |
Global warming |
kg.eq.CO2 |
6.45E+2 |
3.65E+2 |
1.08E+1 |
2.08E+0 |
2.6E+2 |
7.07E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Ozone depletion |
kg.eq.CFC-11 |
4.1E-4 |
1.8E-5 |
2.08E-6 |
1.65E-7 |
3.9E-4 |
3.05E-7 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Acidification of soil and water |
kg.eq.SO2 |
4.76E+0 |
3.24E+0 |
3.57E-2 |
1.7E-2 |
1.46E+0 |
7.28E-3 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Water eutrophication |
kg.eq.P04 3- |
1.67E+0 |
1.39E+0 |
5.97E-3 |
7.12E-3 |
2.56E-1 |
5.31E-3 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Photochemical Ozone formation |
kg.eq.C2H4 |
2.6E-1 |
1.8E-1 |
2.72E-3 |
9.64E-4 |
7.48E-2 |
1.64E-3 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Depletion of abiotic resources - elements |
kg.eq.Sb |
4.75E-2 |
4.49E-2 |
2.04E-5 |
2.25E-4 |
2.37E-3 |
1.97E-6 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Depletion of abiotic resources - fossil fuels |
MJ |
8.77E+3 |
5.27E+3 |
1.72E+2 |
2.97E+1 |
3.27E+3 |
2.81E+1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Water pollution |
m³ |
2.4E+5 |
2.27E+5 |
9.69E+2 |
1.16E+3 |
1.05E+4 |
4.9E+2 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Air pollution |
m³ |
1.65E+5 |
1.29E+5 |
1.46E+3 |
6.69E+2 |
3.35E+4 |
1.96E+2 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of renewable primary energy, excluding renewable primary energy resources used as raw materials |
MJ |
3.19E+3 |
4.05E+2 |
1.47E+0 |
2.33E+0 |
2.78E+3 |
3.96E-1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of renewable primary energy resources used as raw materials |
MJ |
3.58E+2 |
2.65E+2 |
2.88E-1 |
1.34E+0 |
9.13E+1 |
6.05E-2 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Total use of renewable primary energy resources (primary energy and primary energy resources used as raw materials) |
MJ |
3.55E+3 |
6.7E+2 |
1.76E+0 |
3.67E+0 |
2.87E+3 |
4.56E-1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of non-renewable primary energy, excluding non-renewable primary energy resources used as raw materials |
MJ |
6.01E+4 |
6.46E+3 |
1.75E+2 |
4.08E+1 |
5.34E+4 |
2.91E+1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of non-renewable primary energy resources used as raw materials |
MJ |
2.89E+2 |
2.88E+2 |
00E+0 |
1.44E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Total use of non-renewable primary energy resources (primary energy and primary energy resources used as raw materials) |
MJ |
6.04E+4 |
6.75E+3 |
1.75E+2 |
4.22E+1 |
5.34E+4 |
2.91E+1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of secondary materials |
kg |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of renewable secondary fuels |
MJ |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of non-renewable secondary fuels |
MJ |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Net use of fresh water |
m³ |
1.91E+1 |
4.38E+0 |
3.45E-2 |
2.41E-2 |
1.46E+1 |
2.26E-2 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Hazardous waste disposed of |
kg |
3.23E+2 |
3.14E+2 |
1.02E-1 |
1.57E+0 |
7.44E+0 |
2.78E-2 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Non-hazardous waste disposed of |
kg |
9.15E+2 |
6.88E+2 |
1.03E+0 |
4E+0 |
1.48E+2 |
7.49E+1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Radioactive waste disposed of |
kg |
7.33E-1 |
1.56E-2 |
1.18E-3 |
1.71E-4 |
7.16E-1 |
1.78E-4 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Components for re-use |
kg |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Materials for recycling |
kg |
4.23E+1 |
6.1E-1 |
00E+0 |
1.55E+1 |
00E+0 |
2.62E+1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Materials for energy recovery |
kg |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Exported energy |
MJ by energy vector |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Total use of primary energy during the life cycle |
MJ |
6.4E+4 |
7.42E+3 |
1.76E+2 |
4.59E+1 |
5.63E+4 |
2.96E+1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |