ABBG-00214-V01.01

Name of the PEP
ABB DSX301C/DS301C DIFFE RENTIAL CIRCUIT BREAKE RS
Trademark / Owner
ABB ASEA BROWN BOVERI
ABB ASEA BROWN BOVERI LTD
Collective PEP
No
Product classification
  • Installation wiring devices for electric power and communication networks (≤ 63 amperes)
  • Electrical Switchgear and Controlgear Solutions for cabinet
  • Earth leakage protection devices protecting against electric shock
  • Differential circuit breaker
Date of publication
2023/08/01
Date of end of validity
2028/08/01
Date of verification
2023/09/22
PCR
PEP-PCR-ed4-2021 09 06
PSR
PSR-0005-ed2-2016 03 29
Use lifte time
20 years
Reference Product
2CSR255165R1165
Energy model used
europe
Total mass
0.19 kg
Constitution
Plastic
26.80 %
0.05000 kg
Metal
27.80 %
0.05200 kg
Other
45.40 %
0.08600 kg
Covered products by list
- 2CSR255165R1065
- 2CSR255165R1105
- 2CSR255165R1135
- 2CSR255165R1165
- 2CSR255165R1205
- 2CSR255165R1064
- 2CSR255165R1104
- 2CSR255165R1134
- 2CSR255165R1164
- 2CSR255165R1204
- 2CSR245163R1164
- 2CSR245163R1064
- 2CSR245163R1104
- 2CSR245163R1204
- 2CSR255063R1205
- 2CSR255063R1104
- 2CSR255063R1105
- 2CSR255063R1204
- 2CSR255063R1065
- 2CSR255063R1164
- 2CSR255063R1165
- 2CSR255063R1064
- 2CSR255063U1134
- 2CSR255063U1135
- 2CSR255063R1135
- 2CSR255063R1134
- 2CSR255063U1165
- 2CSR255063U1104
- 2CSR255063U1105
- 2CSR255063U1164
- 2CSR255164R1134
- 2CSR255164R1135
- 2CSR255163R1205
- 2CSR255163R1105
- 2CSR255163R1204
- 2CSR255163R1104
- 2CSR255163R1065
- 2CSR255163R1165
- 2CSR255163R1064
- 2CSR255163R1164
- 2CSR255163U1134
- 2CSR255163U1135
- 2CSR255164R1064
- 2CSR255164R1065
- 2CSR255164R1164
- 2CSR255164R1165
- 2CSR255163R1135
- 2CSR255163R1134
- 2CSR255164R1104
- 2CSR255164R1105
- 2CSR255164R1204
- 2CSR255164R1205
- 2CSR255165U1134
- 2CSR255163U1105
- 2CSR255163U1104
- 2CSR255165U1165
- 2CSR255163U1165
- 2CSR255165U1164
- 2CSR255163U1164
Covered products or brand by text
DSX301C B6 A30DSX301C B10 A30DSX301C B13 A30DSX301C B16 A30DSX301C B20 A30DSX301C C6 A30DSX301C C10 A30DSX301C C13 A30DSX301C C16 A30DSX301C C20 A30DS301C L C16 A30DS301C L C6 A30DS301C L C10 A30DS301C L C20 A30DS301C B20 AC30DS301C C10 AC30DS301C B10 AC30DS301C C20 AC30DS301C B6 AC30DS301C C16 AC30DS301C B16 AC30DS301C C6 AC30DS301C C13 AC30DS301C B13 AC30DS301C B13 AC30DS301C C13 AC30DS301C B16 AC30DS301C C10 AC30DS301C B10 AC30DS301C C16 AC30DS301CT C13 A30DS301CT B13 A30DS301C B20 A30DS301C B10 A30DS301C C20 A30DS301C C10 A30DS301C B6 A30DS301C B16 A30DS301C C6 A30DS301C C16 A30DS301C C13 A30DS301C B13 A30DS301CT C6 A30DS301CT B6 A30DS301CT C16 A30DS301CT B16 A30DS301C B13 A30DS301C C13 A30DS301CT C10 A30DS301CT B10 A30DS301CT C20 A30DS301CT B20 A30DSX301C C13 A30DS301C B10 A30DS301C C10 A30DSX301C B16 A30DS301C B16 A30DSX301C C16 A30DS301C C16 A30
Functional Unit
1 unit
Description
The functional unit for the DSX301C/DS301C Type A is “Protect during 20 years the installation against overloads and short-circuits and people and premises at risk of fire or explosion against insulation defects in circuit with assigned voltage 230 V and rated current 16A.
Indicator Unit Total Manufacturing Distribution Installation Use End of Life Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
Benefits and loads beyond the system boundaries
D
Climate change - total kg.eq.CO2 1.65E+1 1.38E+0 1.28E-1 1.26E-1 1.48E+1 7.18E-2 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Climate change - fossil fuels kg.eq.CO2 1.59E+1 1.38E+0 1.28E-1 8.79E-3 1.43E+1 6.93E-2 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Climate change - biogenics kg.eq.CO2 5.83E-1 2.97E-3 1.19E-4 1.17E-1 4.61E-1 2.5E-3 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Climate change - land use and land use transformation kg.eq.CO2 3.62E-2 2.3E-3 5.02E-5 3.5E-6 3.38E-2 7.16E-5 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Ozone depletion kg.eq.CFC-11 8.7E-7 1.13E-7 3.01E-8 2E-9 7.2E-7 5.28E-9 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Acidification (AP) mole.eq.H+ 1.08E-1 2.43E-2 6.51E-4 5.15E-5 8.13E-2 1.78E-3 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Freshwater eutrophication kg.eq.P 1.65E-2 2E-3 8.29E-6 8.98E-7 1.44E-2 9.32E-5 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Marine aquatic eutrophication kg.eq.N 1.67E-2 2.67E-3 2.24E-4 2.93E-5 1.36E-2 2.07E-4 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Terrestrial eutrophication mole.eq.N 1.57E-1 3.35E-2 2.45E-3 2.03E-4 1.19E-1 1.32E-3 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Photochemical ozone formation kg.eq.NMVOC 4.18E-2 7.84E-3 7.03E-4 6.1E-5 3.28E-2 3.99E-4 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Depletion of abiotic resources - elements kg.eq.Sb 8.34E-4 6.59E-4 4.26E-7 2.49E-8 1.34E-4 4.02E-5 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Depletion of abiotic resources - fossil fuels MJ 3.26E+2 1.91E+1 1.97E+0 1.36E-1 3.04E+2 8.08E-1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Water requirement m³.eq.deprivation worldwide 4.71E+0 1.17E+0 6.06E-3 5.64E-4 3.49E+0 3.69E-2 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Emission of fine particles incidence of diseases 3.99E-7 1.2E-7 1.21E-8 1.07E-9 2.59E-7 6.45E-9 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Ionizing radiation, human health kBq.eq.U235 8.49E+0 1.38E-1 1.01E-2 7.86E-4 8.33E+0 1.11E-2 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Ecotoxicity (fresh water) CTUe 4E+2 1.96E+2 1.53E+0 1.26E-1 1.93E+2 1.01E+1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Human toxicity, carcinogenic effects CTUh 1.29E-8 5.74E-9 4.85E-11 1.02E-11 5.93E-9 1.22E-9 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Human toxicity, non-carcinogenic effects CTUh 4.64E-7 2.4E-7 1.62E-9 1.42E-10 1.89E-7 3.31E-8 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Impacts related to land use/soil quality - 8.33E+1 2.58E+1 1.49E+0 1.5E-1 5.5E+1 9.29E-1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Use of renewable primary energy, excluding renewable primary energy resources used as raw materials MJ 3.26E+2 1.91E+1 1.97E+0 1.36E-1 3.04E+2 8.07E-1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Use of renewable primary energy resources used as raw materials MJ 6.91E+1 6.28E+0 2.73E-2 2.81E-3 6.27E+1 1.25E-1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Total use of renewable primary energy resources (primary energy and primary energy resources used as raw materials) MJ 2.56E-1 2.56E-1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Use of non-renewable primary energy, excluding non-renewable primary energy resources used as raw materials MJ 3.96E+2 2.57E+1 1.99E+0 1.38E-1 3.67E+2 9.33E-1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Use of non-renewable primary energy resources used as raw materials MJ 3.25E+2 1.79E+1 1.97E+0 1.36E-1 3.04E+2 8.07E-1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Total use of non-renewable primary energy resources (primary energy and primary energy resources used as raw materials) MJ 1.23E+0 1.23E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Net use of fresh water 2.96E-1 2.99E-2 2.22E-4 3.72E-5 2.65E-1 1.11E-3 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Total use of primary energy during the life cycle MJ 6.94E+1 6.54E+0 2.73E-2 2.81E-3 6.27E+1 1.25E-1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Hazardous waste disposed of kg 4.53E-4 2.04E-4 5.07E-6 3.2E-7 2.32E-4 1.23E-5 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Non-hazardous waste disposed of kg 1.59E+0 2.91E-1 1.14E-1 3.56E-2 1.06E+0 8.95E-2 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Radioactive waste disposed of kg 2.31E-3 5.14E-5 1.33E-5 9.06E-7 2.24E-3 4.41E-6 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Materials for recycling kg 1.4E-1 5.43E-2 00E+0 3.31E-2 00E+0 5.26E-2 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Exported energy MJ by energy vector 1.46E-1 00E+0 00E+0 1.11E-1 00E+0 3.54E-2 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Biogenic carbon content of the associated packaging kg of C 3.64E+2 3.64E+2 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0