LGRP-00346-V01.01

Name of the PEP
Telephone surge protection
Trademark / Owner
LEGRAND
LEGRAND
Collective PEP
No
Product classification
  • Installation wiring devices for electric power and communication networks (≤ 63 amperes)
  • Electrical Switchgear and Controlgear Solutions for cabinet
  • Surge protective devices
  • Surge protective devices for communication networks
Date of publication
2017/11/17
Date of end of validity
2022/11/17
Date of verification
-
PCR
PEP-PCR-ed3-2015 04 02
PSR
PSR-0005-ed2-2016 03 29
Use lifte time
20 years
Reference Product
412200
Energy model used
Electricity Mix; Europe 27 (2002)
Total mass
99.83 g
Constitution
Plastic
24.64 %
Metal
9.40 %
Other
65.96 %
Comments
0
Covered products or brand by text
412200, 412201, 927610
Functional Unit
1 unit
Description
Protect during 20 years against direct or indirect effects of lightning or against transient overvoltages electronical equipements connected to connected to elecommunications and signalling networks with a rated operational voltage up to 1000 V AC (rms) or 1500 V DC
Extrapolation Rules
<description de la règle d'extrapolation à appliquer pour estimer les impacts des produits autres que ceux constituant le Produit de Référence.>
Indicator Unit Total Manufacturing Distribution Installation Use End of Life Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
Benefits and loads beyond the system boundaries
D
Global warming kg.eq.CO2 9.38E+1 1.7E+0 3.88E-3 2.31E-3 9.21E+1 6.32E-3 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Ozone depletion kg.eq.CFC-11 2.26E-5 1.92E-7 7.85E-12 8.89E-12 2.24E-5 1.5E-10 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Acidification of soil and water kg.eq.SO2 6.98E-1 1.8E-3 1.74E-5 1.07E-5 6.96E-1 2.43E-5 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Water eutrophication kg.eq.P04 3- 2.69E-2 7.3E-4 4E-6 6.12E-6 2.61E-2 2.91E-5 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Photochemical Ozone formation kg.eq.C2H4 3.32E-2 2.47E-4 1.24E-6 7.61E-7 3.29E-2 1.89E-6 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Depletion of abiotic resources - elements kg.eq.Sb 1.41E-4 1.37E-4 1.55E-10 9.55E-11 4.19E-6 3.94E-10 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Depletion of abiotic resources - fossil fuels MJ 9.69E+2 2.01E+1 5.45E-2 3.23E-2 9.48E+2 8.96E-2 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Water pollution 4.19E+3 3.21E+2 6.37E-1 3.71E-1 3.86E+3 7.32E-1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Air pollution 4.1E+3 1.49E+2 1.59E-1 1.7E-1 3.95E+3 7.13E-1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Use of renewable primary energy, excluding renewable primary energy resources used as raw materials MJ 1.34E+2 4.57E-1 7.3E-5 1.65E-4 1.33E+2 1.61E-3 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Use of renewable primary energy resources used as raw materials MJ 8.01E-1 8.01E-1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Total use of renewable primary energy resources (primary energy and primary energy resources used as raw materials) MJ 1.35E+2 1.26E+0 7.3E-5 1.65E-4 1.33E+2 1.61E-3 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Use of non-renewable primary energy, excluding non-renewable primary energy resources used as raw materials MJ 1.47E+3 1.93E+1 5.19E-2 3.06E-2 1.45E+3 6.62E-2 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Use of non-renewable primary energy resources used as raw materials MJ 1.24E+0 1.24E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Total use of non-renewable primary energy resources (primary energy and primary energy resources used as raw materials) MJ 1.48E+3 2.05E+1 5.19E-2 3.06E-2 1.45E+3 6.62E-2 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Use of secondary materials kg 5.71E-3 5.71E-3 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Use of renewable secondary fuels MJ 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Use of non-renewable secondary fuels MJ 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Net use of fresh water 2.48E-1 7.89E-3 3.47E-7 4.02E-7 2.4E-1 5.19E-6 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Hazardous waste disposed of kg 6.17E-1 6.17E-1 00E+0 3.2E-6 00E+0 2.59E-5 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Non-hazardous waste disposed of kg 3.45E+2 2.8E-1 1.38E-4 1.46E-2 3.44E+2 6.28E-2 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Radioactive waste disposed of kg 2.81E-1 1.34E-4 9.81E-8 1.11E-7 2.81E-1 1.87E-6 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Components for re-use kg 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Materials for recycling kg 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Materials for energy recovery kg 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Exported energy MJ by energy vector 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0
Total use of primary energy during the life cycle MJ 1.61E+3 2.18E+1 5.2E-2 3.08E-2 1.59E+3 6.78E-2 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 0