CHAP-00006-V01.01

Name of the PEP
Eria-N
Trademark / Owner
CHAPPÉE
BDR THERMEA GROUP
Collective PEP
No
Product classification
  • Heating, ventilation and air conditioning equipement
  • Heating and/or air conditioning and/or hot water heating
  • Domestic heat pumps
  • Air/Water
Date of publication
2021/03/26
Date of end of validity
2026/03/26
PCR
PEP-PCR-ed3-2015 04 02
PSR
PSR-0013-ed2-2019 12 06
Use lifte time
17 years
Reference Product
Eira-N 6 EM Mono - 7778441
Energy model used
France
Total mass
88.9 kg
Constitution
Plastic
8.10 %
Metal
71.00 %
Other
20.90 %
Covered products or brand by text
Eria-N 4.5 HM Mono 7778447 Eria-N 4.5 EM Mono 7778440 Eria-N 6 HM Mono 7778448 Eria-N 8 HM Mono 7778449 Eria-N 8 EM Mono 7778442 Eria-N 11 HM Mono 7778450 Eria-N 11 EM Mono 7778443 Eria-N 11 HT Tri 7778451 Eria-N 11 ET Tri 7778444 Eria-N 16 HM Mono 7778452 Eria-N 16 EM Mono 7778445 Eria-N 16 HT Tri 7778453 Eria-N 16 ET Tri 7778446
Functional Unit
1 kW
Description
Produire 1 kW de chauffage, selon le scénario d’usage approprié défini dans la norme EN14825 et pendant une durée de vie de référence de 17 ans du produit
Indicator Unit Total Manufacturing Distribution Installation Use End of Life Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
Global warming kg.eq.CO2 1.67E+3 1.84E+2 1.23E+0 9.68E+0 1.39E+3 8.52E+1 2.31E+2 6.69E+1 00E+0 00E+0 00E+0 1.09E+3 00E+0
Ozone depletion kg.eq.CFC-11 1.63E-3 1.6E-5 2.49E-9 8E-7 1.61E-3 1.89E-8 1.86E-8 4.45E-5 00E+0 00E+0 00E+0 1.56E-3 00E+0
Acidification of soil and water kg.eq.SO2 4.69E+0 4.41E-1 5.52E-3 2.1E-2 4.22E+0 2.94E-3 1.95E-4 1.46E-1 00E+0 00E+0 00E+0 4.07E+0 00E+0
Water eutrophication kg.eq.P04 3- 5.28E-1 8.91E-2 1.27E-3 1.91E-2 4.11E-1 7.86E-3 5.55E-5 3.98E-2 00E+0 00E+0 00E+0 3.71E-1 00E+0
Photochemical Ozone formation kg.eq.C2H4 3.62E-1 4.17E-2 3.92E-4 2.66E-3 3.17E-1 2.19E-4 3.4E-5 8.17E-2 00E+0 00E+0 00E+0 2.36E-1 00E+0
Depletion of abiotic resources - elements kg.eq.Sb 1.89E-2 1.83E-2 4.92E-8 2.47E-5 5.34E-4 2.15E-8 1.18E-8 2.75E-8 00E+0 00E+0 00E+0 5.34E-4 00E+0
Depletion of abiotic resources - fossil fuels MJ 1.52E+4 1.67E+3 1.73E+1 8.04E+1 1.34E+4 4.23E+0 6.48E+0 8.06E+2 00E+0 00E+0 00E+0 1.26E+4 00E+0
Water pollution 8.15E+4 1.49E+4 2.02E+2 1.09E+3 6.47E+4 5.76E+2 1.21E+1 9.31E+3 00E+0 00E+0 00E+0 5.54E+4 00E+0
Air pollution 9.94E+4 2.45E+4 5.04E+1 8.95E+2 7.08E+4 3.16E+3 8.75E+3 2.56E+4 00E+0 00E+0 00E+0 3.65E+4 00E+0
Use of renewable primary energy, excluding renewable primary energy resources used as raw materials MJ 7.27E+3 2.88E+1 2.32E-2 00E+0 7.24E+3 5.18E-2 3.3E-4 1.15E-2 00E+0 00E+0 00E+0 7.24E+3 00E+0
Use of renewable primary energy resources used as raw materials MJ 5.43E+1 4.96E+1 00E+0 4.73E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Total use of renewable primary energy resources (primary energy and primary energy resources used as raw materials) MJ 7.32E+3 7.84E+1 2.32E-2 3.18E+0 7.24E+3 5.18E-2 3.3E-4 1.15E-2 00E+0 00E+0 00E+0 7.24E+3 00E+0
Use of non-renewable primary energy, excluding non-renewable primary energy resources used as raw materials MJ 9.74E+4 3.61E+3 1.74E+1 3.67E+2 9.34E+4 4.92E+0 2.1E+0 8.12E+2 00E+0 00E+0 00E+0 9.26E+4 00E+0
Use of non-renewable primary energy resources used as raw materials MJ 1.49E+2 1.38E+2 00E+0 6.35E+0 4.97E+0 00E+0 4.97E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Total use of non-renewable primary energy resources (primary energy and primary energy resources used as raw materials) MJ 9.76E+4 3.75E+3 1.74E+1 3.73E+2 9.34E+4 4.92E+0 7.08E+0 8.12E+2 00E+0 00E+0 00E+0 9.26E+4 00E+0
Use of secondary materials kg 1.32E+1 1.18E+1 00E+0 1.39E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Use of renewable secondary fuels MJ 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Use of non-renewable secondary fuels MJ 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Net use of fresh water 2.59E+4 1.22E+1 1.1E-4 1.17E+0 2.59E+4 7.33E-3 5.86E-4 8.35E-2 00E+0 00E+0 00E+0 2.59E+4 00E+0
Hazardous waste disposed of kg 1.92E+2 1.82E+2 00E+0 8.42E+0 2.17E+0 1.87E-3 4.89E-3 9.76E-2 00E+0 00E+0 00E+0 2.06E+0 00E+0
Non-hazardous waste disposed of kg 2.4E+3 1.34E+2 4.37E-2 1.01E+1 2.24E+3 1.39E+1 2.12E-3 1.29E-1 00E+0 00E+0 00E+0 2.24E+3 00E+0
Radioactive waste disposed of kg 3.31E+1 3.24E-2 3.11E-5 2.37E-3 3.31E+1 6.32E-5 5.88E-6 1.28E-2 00E+0 00E+0 00E+0 3.3E+1 00E+0
Components for re-use kg 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Materials for recycling kg 8.66E+0 1.13E+0 00E+0 2.95E+0 00E+0 4.58E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Materials for energy recovery kg 5.25E+0 7.96E-8 00E+0 3.57E-1 00E+0 4.89E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Exported energy MJ by energy vector 3.16E-1 3.21E-2 00E+0 3.3E-2 00E+0 2.51E-1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Total use of primary energy during the life cycle MJ 1.05E+5 3.83E+3 1.74E+1 3.76E+2 1.01E+5 4.97E+0 7.08E+0 8.12E+2 00E+0 00E+0 00E+0 9.99E+4 00E+0
Functional Unit
1 unit
Description
Pompe à chaleur air/eau d’une puissance de XX* kW assurant la fonction de fournir de la chaleur à un logement individuel pour une durée de vie de référence de 17 ans (la puissance est à ajuster en fonction du produit considéré de la gamme)
Indicator Unit Total Manufacturing Distribution Installation Use End of Life Use
B1
Maintenance
B2
Repair
B3
Replacement
B4
Refurbishment
B5
Operational energy use
B6
Operational water use
B7
Global warming kg.eq.CO2 6.02E+3 6.61E+2 4.42E+0 3.49E+1 5.01E+3 3.07E+2 8.32E+2 2.41E+2 00E+0 00E+0 00E+0 3.94E+3 00E+0
Ozone depletion kg.eq.CFC-11 5.85E-3 5.77E-5 8.96E-9 2.88E-6 5.79E-3 6.79E-8 6.7E-8 1.6E-4 00E+0 00E+0 00E+0 5.63E-3 00E+0
Acidification of soil and water kg.eq.SO2 1.69E+1 1.59E+0 1.99E-2 7.54E-2 1.52E+1 1.06E-2 7.03E-4 5.25E-1 00E+0 00E+0 00E+0 1.47E+1 00E+0
Water eutrophication kg.eq.P04 3- 1.9E+0 3.21E-1 4.57E-3 6.89E-2 1.48E+0 2.83E-2 2E-4 1.43E-1 00E+0 00E+0 00E+0 1.34E+0 00E+0
Photochemical Ozone formation kg.eq.C2H4 1.3E+0 1.5E-1 1.41E-3 9.59E-3 1.14E+0 7.89E-4 1.23E-4 2.94E-1 00E+0 00E+0 00E+0 8.48E-1 00E+0
Depletion of abiotic resources - elements kg.eq.Sb 6.8E-2 6.59E-2 1.77E-7 8.9E-5 1.92E-3 7.73E-8 4.26E-8 9.9E-8 00E+0 00E+0 00E+0 1.92E-3 00E+0
Depletion of abiotic resources - fossil fuels MJ 5.46E+4 6E+3 6.21E+1 2.89E+2 4.82E+4 1.52E+1 2.33E+1 2.9E+3 00E+0 00E+0 00E+0 4.53E+4 00E+0
Water pollution 2.93E+5 5.36E+4 7.27E+2 3.92E+3 2.33E+5 2.08E+3 4.37E+1 3.35E+4 00E+0 00E+0 00E+0 1.99E+5 00E+0
Air pollution 3.58E+5 8.84E+4 1.81E+2 3.22E+3 2.55E+5 1.14E+4 3.15E+4 9.2E+4 00E+0 00E+0 00E+0 1.31E+5 00E+0
Use of renewable primary energy, excluding renewable primary energy resources used as raw materials MJ 2.62E+4 1.04E+2 8.34E-2 00E+0 2.61E+4 1.87E-1 1.19E-3 4.14E-2 00E+0 00E+0 00E+0 2.61E+4 00E+0
Use of renewable primary energy resources used as raw materials MJ 1.96E+2 1.79E+2 00E+0 1.7E+1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Total use of renewable primary energy resources (primary energy and primary energy resources used as raw materials) MJ 2.64E+4 2.82E+2 8.34E-2 1.15E+1 2.61E+4 1.87E-1 1.19E-3 4.14E-2 00E+0 00E+0 00E+0 2.61E+4 00E+0
Use of non-renewable primary energy, excluding non-renewable primary energy resources used as raw materials MJ 3.51E+5 1.3E+4 6.25E+1 1.32E+3 3.36E+5 1.77E+1 7.58E+0 2.92E+3 00E+0 00E+0 00E+0 3.33E+5 00E+0
Use of non-renewable primary energy resources used as raw materials MJ 5.36E+2 4.95E+2 00E+0 2.29E+1 1.79E+1 00E+0 1.79E+1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Total use of non-renewable primary energy resources (primary energy and primary energy resources used as raw materials) MJ 3.51E+5 1.35E+4 6.25E+1 1.34E+3 3.36E+5 1.77E+1 2.55E+1 2.92E+3 00E+0 00E+0 00E+0 3.33E+5 00E+0
Use of secondary materials kg 4.73E+1 4.24E+1 00E+0 4.99E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Use of renewable secondary fuels MJ 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Use of non-renewable secondary fuels MJ 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Net use of fresh water 9.34E+4 4.38E+1 3.96E-4 4.21E+0 9.33E+4 2.64E-2 2.11E-3 3E-1 00E+0 00E+0 00E+0 9.33E+4 00E+0
Hazardous waste disposed of kg 6.92E+2 6.54E+2 00E+0 3.03E+1 7.8E+0 6.73E-3 1.76E-2 3.51E-1 00E+0 00E+0 00E+0 7.43E+0 00E+0
Non-hazardous waste disposed of kg 8.63E+3 4.82E+2 1.57E-1 3.63E+1 8.06E+3 4.99E+1 7.64E-3 4.66E-1 00E+0 00E+0 00E+0 8.06E+3 00E+0
Radioactive waste disposed of kg 1.19E+2 1.17E-1 1.12E-4 8.55E-3 1.19E+2 2.27E-4 2.12E-5 4.62E-2 00E+0 00E+0 00E+0 1.19E+2 00E+0
Components for re-use kg 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Materials for recycling kg 3.12E+1 4.06E+0 00E+0 1.06E+1 00E+0 1.65E+1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Materials for energy recovery kg 1.89E+1 2.87E-7 00E+0 1.29E+0 00E+0 1.76E+1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Exported energy MJ by energy vector 1.14E+0 1.15E-1 00E+0 1.19E-1 00E+0 9.04E-1 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0 00E+0
Total use of primary energy during the life cycle MJ 3.78E+5 1.38E+4 6.25E+1 1.35E+3 3.62E+5 1.79E+1 2.55E+1 2.92E+3 00E+0 00E+0 00E+0 3.59E+5 00E+0