Description
To protect the load of 1.984 Watts against input power failure during 8 years and provide a backup time of 2,5 minutes for 100% of load and a backup time of 150 minutes for a typical applicationin case of a power outage. Product dimensions is 307x190x484; AxLxP(mm); Monomode VI; redundancy no; power factor = 0,62, location of the manufacturing plant : Brazil; Mass without energy storage system e.g. batteries with packaging : 23 101 g; Mass of energy storage system if incorporated : 11 000 g; Input Dependency Characteristics according to IEC 62040-3 : VFI, monomode.
Indicator | Unit | Total | Manufacturing | Distribution | Installation | Use | End of Life | Use B1 | Maintenance B2 | Repair B3 | Replacement B4 | Refurbishment B5 | Operational energy use B6 | Operational water use B7 |
Global warming | kg.eq.CO2 | 1.74E+3 | 2.33E+2 | 2.83E+0 | 1.03E-1 | 1.51E+3 | 3.62E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Ozone depletion | kg.eq.CFC-11 | 2.45E-4 | 4.33E-5 | 2.01E-6 | 7.52E-10 | 1.99E-4 | 8.66E-8 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Acidification of soil and water | kg.eq.SO2 | 1.55E+0 | 3.19E-1 | 7.61E-3 | 4.75E-4 | 1.21E+0 | 1.39E-2 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Water eutrophication | kg.eq.P04 3- | 4.16E-1 | 8.06E-2 | 2.04E-3 | 3.73E-4 | 3.17E-1 | 1.66E-2 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Photochemical Ozone formation | kg.eq.C2H4 | 3.64E-1 | 5.61E-2 | 1.65E-4 | 3.4E-5 | 3.07E-1 | 1.08E-3 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Depletion of abiotic resources - elements | kg.eq.Sb | 1.01E-1 | 6.57E-2 | 5.18E-10 | 4.59E-9 | 3.58E-2 | 2.26E-7 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Depletion of abiotic resources - fossil fuels | MJ | 1.92E+4 | 3.42E+3 | 3.57E+1 | 1.44E+0 | 1.57E+4 | 5.14E+1 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Water pollution | m³ | 1.07E+5 | 3.46E+4 | 4.18E+2 | 1.57E+1 | 7.17E+4 | 4.19E+2 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Air pollution | m³ | 1.98E+5 | 6.74E+4 | 9.95E+1 | 9.7E+0 | 1.3E+5 | 4.1E+2 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Use of renewable primary energy, excluding renewable primary energy resources used as raw materials | MJ | 3.01E+4 | 6.45E+0 | 2.34E-4 | 1.24E-2 | 3.01E+4 | 9.29E-1 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Use of renewable primary energy resources used as raw materials | MJ | 2.88E+1 | 2.88E+1 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Total use of renewable primary energy resources (primary energy and primary energy resources used as raw materials) | MJ | 3.01E+4 | 3.52E+1 | 2.34E-4 | 1.24E-2 | 3.01E+4 | 9.29E-1 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Use of non-renewable primary energy, excluding non-renewable primary energy resources used as raw materials | MJ | 1.67E+4 | 4.27E+3 | 3.5E+1 | 1.32E+0 | 1.24E+4 | 3.79E+1 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Use of non-renewable primary energy resources used as raw materials | MJ | 2.45E+2 | 1.6E+2 | 00E+0 | 00E+0 | 8.55E+1 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Total use of non-renewable primary energy resources (primary energy and primary energy resources used as raw materials) | MJ | 1.7E+4 | 4.43E+3 | 3.5E+1 | 1.32E+0 | 1.25E+4 | 3.79E+1 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Use of secondary materials | kg | 2.22E+0 | 2.22E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Use of renewable secondary fuels | MJ | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Use of non-renewable secondary fuels | MJ | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Net use of fresh water | m³ | 4.9E+0 | 1.82E+0 | 3.4E-3 | 3.07E-5 | 3.07E+0 | 3E-3 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Hazardous waste disposed of | kg | 9.65E+1 | 4.33E+1 | 2.39E-3 | 2.48E-4 | 5.31E+1 | 1.49E-2 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Non-hazardous waste disposed of | kg | 1.93E+2 | 2.07E+1 | 2.93E-3 | 9.94E-1 | 1.35E+2 | 3.58E+1 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Radioactive waste disposed of | kg | 1.24E-1 | 2.96E-2 | 5.73E-4 | 9.38E-6 | 9.27E-2 | 1.08E-3 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Components for re-use | kg | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Materials for recycling | kg | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Materials for energy recovery | kg | 2.01E-7 | 1E-7 | 00E+0 | 00E+0 | 1E-7 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Exported energy | MJ by energy vector | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |
Total use of primary energy during the life cycle | MJ | 4.71E+4 | 4.46E+3 | 3.5E+1 | 1.33E+0 | 4.25E+4 | 3.88E+1 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 | 00E+0 |