Description
Transporter de l’énergie exprimée pour 1 A sur une distance de 1 km pendant 30 années et un taux d’utilisation de 70 %, en conformité avec les caractéristiques techniques des produits.
La durée et le taux d’utilisation correspondent à l’application ‘Résidentiel / Tertiaire / industriel’ telle que définie dans le tableau donné en Annexe 1 des règles spécifiques aux Fils, Câbles et Matériels de raccordement.
Indicator |
Unit |
Total |
Manufacturing |
Distribution |
Installation |
Use |
End of Life |
Use B1 |
Maintenance B2 |
Repair B3 |
Replacement B4 |
Refurbishment B5 |
Operational energy use B6 |
Operational water use B7 |
Global warming |
kg.eq.CO2 |
3.14E+2 |
2.52E+2 |
6.63E+0 |
1.78E+0 |
5.17E+1 |
1.49E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Ozone depletion |
kg.eq.CFC-11 |
9.75E-5 |
1.86E-5 |
1.27E-6 |
1.45E-7 |
7.74E-5 |
9.68E-8 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Acidification of soil and water |
kg.eq.SO2 |
4.23E+0 |
3.89E+0 |
2.18E-2 |
2.03E-2 |
2.9E-1 |
2E-3 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Water eutrophication |
kg.eq.P04 3- |
2.6E+0 |
2.53E+0 |
3.65E-3 |
1.3E-2 |
5.09E-2 |
1.08E-3 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Photochemical Ozone formation |
kg.eq.C2H4 |
2.04E-1 |
1.86E-1 |
1.66E-3 |
1.05E-3 |
1.49E-2 |
3.49E-4 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Depletion of abiotic resources - elements |
kg.eq.Sb |
8.53E-2 |
8.44E-2 |
1.25E-5 |
4.23E-4 |
4.71E-4 |
7.57E-7 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Depletion of abiotic resources - fossil fuels |
MJ |
4.28E+3 |
3.5E+3 |
1.05E+2 |
2.08E+1 |
6.49E+2 |
8.35E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Water pollution |
m³ |
7.76E+4 |
7.44E+4 |
5.93E+2 |
4.09E+2 |
2.09E+3 |
1.07E+2 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Air pollution |
m³ |
1.96E+5 |
1.88E+5 |
8.94E+2 |
9.62E+2 |
6.66E+3 |
6.33E+1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of renewable primary energy, excluding renewable primary energy resources used as raw materials |
MJ |
1.03E+3 |
4.71E+2 |
8.98E-1 |
2.51E+0 |
5.52E+2 |
1.14E-1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of renewable primary energy resources used as raw materials |
MJ |
1.88E+2 |
1.69E+2 |
1.76E-1 |
8.56E-1 |
1.81E+1 |
1.69E-2 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Total use of renewable primary energy resources (primary energy and primary energy resources used as raw materials) |
MJ |
1.22E+3 |
6.4E+2 |
1.07E+0 |
3.37E+0 |
5.7E+2 |
1.31E-1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of non-renewable primary energy, excluding non-renewable primary energy resources used as raw materials |
MJ |
1.52E+4 |
4.41E+3 |
1.07E+2 |
2.75E+1 |
1.06E+4 |
8.87E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of non-renewable primary energy resources used as raw materials |
MJ |
1.75E+2 |
1.74E+2 |
00E+0 |
8.69E-1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Total use of non-renewable primary energy resources (primary energy and primary energy resources used as raw materials) |
MJ |
1.53E+4 |
4.58E+3 |
1.07E+2 |
2.84E+1 |
1.06E+4 |
8.87E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of secondary materials |
kg |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of renewable secondary fuels |
MJ |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Use of non-renewable secondary fuels |
MJ |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Net use of fresh water |
m³ |
6.75E+0 |
3.8E+0 |
2.11E-2 |
2.12E-2 |
2.9E+0 |
4.82E-3 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Hazardous waste disposed of |
kg |
5.79E+2 |
5.75E+2 |
6.22E-2 |
2.88E+0 |
1.48E+0 |
6.99E-3 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Non-hazardous waste disposed of |
kg |
1.32E+3 |
1.27E+3 |
6.32E-1 |
1.07E+1 |
2.93E+1 |
1.36E+1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Radioactive waste disposed of |
kg |
1.6E-1 |
1.63E-2 |
7.19E-4 |
1.33E-4 |
1.42E-1 |
5.83E-5 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Components for re-use |
kg |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Materials for recycling |
kg |
5.75E+1 |
3.66E-1 |
00E+0 |
6.67E+0 |
00E+0 |
5.05E+1 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Materials for energy recovery |
kg |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Exported energy |
MJ by energy vector |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
Total use of primary energy during the life cycle |
MJ |
1.66E+4 |
5.22E+3 |
1.08E+2 |
3.18E+1 |
1.12E+4 |
9.01E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |
00E+0 |